LPG and Ammonia Tank Containers TCM5-25 A,B,C,D
Technical Characteristics

Tank-containers Main page 
Description (ISO Standard)
Technical specification (ISO Standard)
home about company contacts  List of the goods

 

TECHNICAL CHARACTERISTICS OF THE  LPG  TANK-CONTAINER 
TCM5-25A (bottom discharge)  and
TCM5-25C (top discharge)

Parameter Parameter value
Container type UN T50 (IMO 5)
Maximum gross mass, kg 24000
Tare mass, kg 8930
Maximum payload, kg 15070
Tank Capacity, liters (deviation from the nominal, %) 24700 (±1%)
Maximum filling rate, kg/l 0.61
Maximum allowable working pressure, MPa 1.8
Test pressure, Mpa 2.7
Set pressure, MPa 1.85
Full flow pressure (no less than), MPa 1.98
Bursting disk break pressure (if installed) not more than, kg 1.98
Maximum allowable mass of top containers at stockpiling, kg 192000
Internal diameter of tank shell, mm 2375
Internal diameter of dished ends, mm 2375
Type of dished ends Elliptical, the ratio of dished end depth to its internal diameter is 1/4
Nominal wall thickness of the tank shell, mm 16
Nominal wall thickness of dished ends, mm 17
Overall dimentions, mm

Length
Width
Height

 

60580-6
24380-5
26700-5

Center to center distance of coner castings apertures, mm

By length
By height

 

5853±3
2259±3

Safety valve   Fort Vale 006/22685
Bursting disk and pressure gauge may be installed at customers request
Liquid phase loading/discharge device    Fort Vale footvalve, 252/3750 ballvalve 370/3335, outlets 252/0077. Flow diameter 50mm, connection - standard 3¼
Gas phase loading/discharge device    Fort Vale footvalve, 252/3760 ballvalve 370/3335, outlets 252/0087. Flow diameter 50mm, connection - standard 1¾
Manhole Internal diameter 500mm compression outline and control of pressurization are outside the container
Cargo level gauge Two level ultrasonic device with no cargo vapour outlet into the atnosphere
Sun and fire shield Two-ply, with a special fire prevention covering
Temperature operation range, °C -40 ... +55
Tank material Low alloy steel 09G2S-14, GOST5520-79
P355NL1, P355NL2
DIN 10028-3
Material of the end frames and elements fastening the tank to the frames Low alloy steel 09G2S-14, GOST19281-89
Time before the safety relief valve operates in conditions of a fire of petroleum products (not less than), min 60
Terms of operation (up to write-off), years 30

 

 

TECHNICAL CHARACTERISTICS OF THE  AMMONIA  TANK-CONTAINER 
TCM5-25B (bottom discharge)  and
TCM5-25D (top discharge)

Parameter Parameter value
Container type UN T50 (IMO 5)
Maximum gross mass, kg 24000
Tare mass, kg 10130
Maximum payload, kg 13870
Tank Capacity, liters (deviation from the nominal, %) 24700 (±1%)
Maximum filling rate, kg/l 0.56
Maximum allowable working pressure, MPa 2.2
Test pressure, Mpa 3.3
Set pressure, MPa 2.25
Full flow pressure (no less than), MPa 2.42
Bursting disk break pressure (if installed) not more than, kg 2.42
Maximum allowable mass of top containers at stockpiling, kg 192000
Internal diameter of tank shell, mm 2375
Internal diameter of dished ends, mm 2375
Type of dished ends Elliptical, the ratio of dished end depth to its internal diameter is 1/4
Nominal wall thickness of the tank shell, mm 20
Nominal wall thickness of dished ends, mm 20
Overall dimentions, mm

Length
Width
Height

 

60580-6
24380-5
26700-5

Center to center distance of coner castings apertures, mm

By length
By height

 

5853±3
2259±3

Safety valve   Fort Vale 006/22685
Bursting disk and pressure gauge may be installed at customers request
Liquid phase loading/discharge device    Fort Vale footvalve, 252/3750 ballvalve 370/3335, outlets 252/0077. Flow diameter 50mm, connection - standard 3¼
Gas phase loading/discharge device    Fort Vale footvalve, 252/3760 ballvalve 370/3335, outlets 252/0087. Flow diameter 50mm, connection - standard 1¾
Manhole Internal diameter 500mm compression outline and control of pressurization are outside the container
Cargo level gauge Two level ultrasonic device with no cargo vapour outlet into the atnosphere
Sun and fire shield Two-ply, with a special fire prevention covering
Temperature operation range, °C -40 ... +55
Tank material Low alloy steel 09G2S-14, GOST5520-79
P355NL1, P355NL2
DIN 10028-3
Material of the end frames and elements fastening the tank to the frames Low alloy steel 09G2S-14, GOST19281-89
Time before the safety relief valve operates in conditions of a fire of petroleum products (not less than), min 60
Terms of operation (up to write-off), years 30